Standard Features
 |
Selection of probe tube length options |
 |
Range of flexible hose length options |
 |
Integral flue gas temperature thermocouple (except HT probe) |
 |
Standard, replaceable particulate filter (Standard & DrySamplerTM Probes only) |
Product Range Options
Probe Type |
Measurement capability |
Compatibility |
Max. Flue Gas Temp. |
Probe Length
options (m) |
Probe length
options (ft) |
Options / Ancillaries |
| Standard |
All gases |
Lancom III |
1112 °F / 600 °C |
0.3; 1.0; 1.5; 2.5; 3.0 |
0.9; 3.3; 5; 6.5; 10 |
3 m or 10 m / 10 ft or 33 ft hose available |
| High Temp |
All gases |
Lancom III |
2552 °F / 1400 °C |
0.5; 1.0; 1.5; 2.0 |
1.6; 3.3; 5; 6.5 |
3 m / 10 ft hose available |
| Smoke |
All gases plus Smoke density |
Lancom III |
1112 °F / 600 °C |
0.3; 0.75; 1.0 |
1, 2.4; 3.2 |
3 m / 10 ft hose; Filter papers; Bacharach chart and in-line flowmeter |
| Flow |
All gases plus Flow, velocity, Mass emissions |
Lancom III |
1112 °F / 600 °C |
0.7; 1.2; 2.2; 3.0 |
2.3; 3.9; 7.2; 9.8 |
3 m or 10 m / 10 ft or 33 ft hose available |
| DrySampler |
All gases plus higher performance with soluble gases NO2 & SO2 |
Lancom III |
1112 °F / 600 °C |
0.3; 1.0; 1.5; 2.5; 3.0 |
0.9; 3.3; 5; 6.5; 10 |
3 m or 10 m / 10 ft or 33 ft hose available |

| Standard Sample Probe |
|
| The Standard sample probe is suitable for most applications where the gas temperature is below 1112 °F / 600 °C . An adjustable collar is provided with the probe to prevent air ingress at the measurement point – thus preventing inaccurate readings, and to control the insertion distance into the gas stream. The probe is easily assembled and disassembled to fit inside the carry case. |
 |
| Features |
 |
Adjustable collar to control insertion distance and seal properly with entry port |
|
 |
Replaceable sintered filter tip |
|
 |
High quality steel probe tube |
|
| |
|

| High Temperature Probe |
|
The High Temperature Gas Sample Probe is suitable for most applications where the gas temperature is up to 2552 °F / 1400 °C. A fixed sealing collar is provided with the probe to prevent air ingress at the measurement point – thus preventing inaccurate readings. An adjustable support handle and multiple heat shields ensure the probe can be used safely in high temperature applications. The probe tube is easily removed and replaced.
|
 |
| Features |
|
 |
Unique handle designed to dissipate heat from the sample |
|
 |
Probe tube easily replaced |
|
 |
Special heat-deflecting shield to protect the user from escape of hot process gases |
|
| |
|

| Smoke Probe |
|
The Smoke Probe provides smoke density measurements, by passing the sample gas over a filter paper for a fixed time period. The color change of the filter paper is compared against a Bacharach smoke scale (0 –9) to give a result. The filter paper is easily fitted inside the probe handle. An adjustable collar is provided with the probe to prevent air ingress at the measurement point – thus preventing inaccurate readings, and to control the insertion distance into the gas stream.
|
 |
| Features |
|
 |
Simple to setup and use |
|
 |
Measurement comparison against the Bacharach Smoke Scale |
|
 |
Adjustable collar to control insertion distance and seal properly with entry port |
|
| |
|

| Flow Probe |
|
| The Flow Probe is suitable for most applications where the gas temperature is below 1112 °F / 600 °C. An adjustable collar and handle is provided with the probe to prevent air ingress at the measurement point – thus preventing inaccurate readings, and to control the insertion distance into the gas stream. Flow measurement is made by the Pitot tube design at the top of the probe. The probe is also suitable for measuring gas concentrations. |
 |
| |
|
| Note the Lancom portable gas analyzer must have a revised flow sensor fitted to operate with the flow probe. |
|
| |
|
|

DrySampler Probe
|
|
The DrySampler™ probe both samples and dries the wet flue gas at the measurement point.
The DrySampler™ not only provides a solution but also successfully meets the requirements for practicality and cost.
The DrySampler™ uses a revolutionary design (US Patent No. 6782767), featuring a probe with an integrated sample drying system, which excludes the requirement for expensive, heavy, inconvenient and unreliable separate sample conditioners, heated sample lines and probes.
The unique DrySampler™ probe does not require electrical power and is fully self-contained – making it truly portable, low cost and more importantly very easy to use. The probe plugs straight into any Lancom portable analyzer.
The DrySampler™ is especially successful when monitoring soluble gases such as SO2 and NO2. The probe has been independently performance tested (Ref. National Physical Laboratory Report QE21/02/1042), proving the design and operation produce very accurate and repeatable measurement results. |
 |
| |
|
| Features |
|
 |
Removes moisture from the sample gas at the probe, giving the most accurate and reliable analysis of soluble gases such as NO2 and SO2. |
|
 |
No electric power required |
|
 |
No heated sample lines required |
|
 |
Lightweight and compact |
|
 |
Low cost |
|
 |
Performance verified by independent testing |
|
|